Click to enlarge image
|
Description - E1/Datacom Tester (GAO5854)
This E1/Datacom Tester is a multi-functional, full- featured digital transmission system test device designed for the installation, testing, acceptance, and daily maintenance of digital networks. The E1/Datacom tester is able to perform channel tests, alarm analysis, fault location and signal analysis. In addition, this tester provides various protocol converters with one-way and bi-directional bit-error-rate (BER) test functions. These capabilities make it ideal for filed use.
Basic Functions - E1/Datacom Tester (GAO5854)
E1 BER Tester Capability
- 75Ω and 120Ω line interfaces
- HDB3 and AMI line codes
- Out-of-service 2Mb/s, N×64kb/s BER testing
- In-service framed and unframed testing
- Frame data control and monitoring
- Time slot activity monitoring
- Built-in 64kb/s tone channel listen capability
- CAS and CCS signaling generation and monitoring
- Round trip delay measurement
- APS delay measurement
- Extensive error and alarm generation
- VF tone generation and measurement
- Frequency, clock slip and level measurement
- Up to ±999ppm transmit clock deviation
- Clock source: Internal, Interface or External 2M clock/signal (optional)
- Real-time transmission circuit open/short indication
G.703 CO Testing
- G.703 CO 64kb/s BER testing
- Octet timing control and monitoring
- Frequency and offset measurement
- Clock source: Internal, Interface
Protocol Converter Testing
- E1-Datacom SYNC 64k or N×64kb/s BER testing
- E1-G.703 CO SYNC 64kb/s BER testing
- Frequency and offset measurement
- Handshaking signals monitoring
- E1 frame data monitoring
Other Functions
- Real-time clock
- Test pattern: PRBS, Fixed Code and 16-bit user word
- Error injection: Single and Fixed Rate
- Manual and auto-timer measurement
- ITU-T G.821, G.826, and M.2100 performance analysis
- Self-check and keyboard testing function
Main Features - E1/Datacom Tester (GAO5854)
- Handheld design and easy-to-use
- Full-featured measurements to E1, Datacom and Protocol Converter
- High resolution backlight LCD
- Smart navigation mode displays
- Extensive error and alarm generation, detection and indication
- Histogram analysis of alarm and error events
- Up to 99 days continuance test performance
- Save/Recall of up to 10 user-defined setups and 10 sets of results
- Up to 6 hours operation from a single battery charge
- Built-in NiMH rechargeable batteries and smart charger circuit
- Can be charged with automobile cigarette lighter battery adapter
- Upgradable software via an integrated RS232C interface
- Test results uploaded, conserved and printed by Test Manager software
|
|
|
|
| |
|
|
|